CXM-4

Categories: ,

Description

Generation 4 CXM-4 White LED Pico – COB Arrays

Features

• High lumen output and efficacy typical
• Over 440 lm, 110 LPW @ 3000K, 90CRI, Tj = 85°C
• Over 555 lm, 140 LPW @ 5000K, 80CRI, Tj = 85°C
• CCT range 2200k, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K, 5700K and 6500K
• AccuWhite High Color Rendering, 97CRI Typ. Most CCTs
• 3 SDCM color binning standard, 2 SDCM binning available
• Excellent optical emission uniformity and color over angle consistency
• Exceptional long term color stability
• Superior thermal conductivity for uniform heat spreading

Applications
• Hotel Lighting
• Spotlights/Track Lights
• Downlights
• Shop Lighting
• Hospitality Lighting
• Architectural and Specialty

Ordering Part Numbers – 9 V

The following tables describe products with typical flux and minimum flux measured at 480 mA and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

Minimum-

CRI²

CCT Luminous Flux (Im)¹ Ordering Part Number
Typical Flux

(85°C)

Minimum

Flux (85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
90 2200K 375 350 400 CXM-4-22-90-9-AC40-F5-3 CXM-4-22-90-9-AC40-F5-2
90 2400K 390 365 415 CXM-4-24-90-9-AC40-F5-3 CXM-4-24-90-9-AC40-F5-2
80 2700K 505 470 540 CXM-4-27-80-9-AC40-F5-3 CXM-4-27-80-9-AC40-F5-2
90 415 385 445 CXM-4-27-90-9-AC40-F5-3 CXM-4-27-90-9-AC40-F5-2
95 390 365 415 CXM-4-27-95-9-AC40-F5-3 CXM-4-27-95-9-AC40-F5-2
80 3000K 520 485 555 CXM-4-30-80-9-AC40-F5-3 CXM-4-30-80-9-AC40-F5-2
90 440 410 470 CXM-4-30-90-9-AC40-F5-3 CXM-4-30-90-9-AC40-F5-2
95 405 375 435 CXM-4-30-95-9-AC40-F5-3 CXM-4-30-95-9-AC40-F5-2
80 3500K 540 500 580 CXM-4-35-80-9-AC40-F5-3 CXM-4-35-80-9-AC40-F5-2
90 460 430 490 CXM-4-35-90-9-AC40-F5-3 CXM-4-35-90-9-AC40-F5-2
95 435 405 465 CXM-4-35-95-9-AC40-F5-3 CXM-4-35-95-9-AC40-F5-2
80 4000K 550 510 590 CXM-4-40-80-9-AC40-F5-3 CXM-4-40-80-9-AC40-F5-2
90 465 430 500 CXM-4-40-90-9-AC40-F5-3 CXM-4-40-90-9-AC40-F5-2
95 425 395 455 CXM-4-40-95-9-AC40-F5-3 CXM-4-40-95-9-AC40-F5-2
80 5000K 555 515 595 CXM-4-50-80-9-AC40-F5-3
90 470 435 505 CXM-4-50-90-9-AC40-F5-3
95 410 380 440 CXM-4-50-95-9-AC40-F5-3
80 5700K 550 510 590 CXM-4-57-80-9-AC40-F5-3
80 6500K 545 505 585 CXM-4-65-80-9-AC40-F5-3

 

Ordering Part Numbers – 18 V

The following tables describe products with typical flux and minimum flux measured at 240 mA and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

Minimum-

CRI²

CCT Luminous Flux (Im)¹ Ordering Part Number
Typical Flux

(85°C)

Minimum

Flux (85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
90 2200K 375 350 400 CXM-4-22-90-18-AC40-F5-3 CXM-4-22-90-18-AC40-F5-2
90 2400K 390 365 415 CXM-4-24-90-18-AC40-F5-3 CXM-4-24-90-18-AC40-F5-2
80 2700K 505 470 540 CXM-4-27-80-18-AC40-F5-3 CXM-4-27-80-18-AC40-F5-2
90 415 385 445 CXM-4-27-90-18-AC40-F5-3 CXM-4-27-90-18-AC40-F5-2
95 390 365 415 CXM-4-27-95-18-AC40-F5-3 CXM-4-27-95-18-AC40-F5-2
80 3000K 520 485 555 CXM-4-30-80-18-AC40-F5-3 CXM-4-30-80-18-AC40-F5-2
90 440 410 470 CXM-4-30-90-18-AC40-F5-3 CXM-4-30-90-18-AC40-F5-2
95 405 375 435 CXM-4-30-95-18-AC40-F5-3 CXM-4-30-95-18-AC40-F5-2
80 3500K 540 500 580 CXM-4-35-80-18-AC40-F5-3 CXM-4-35-80-18-AC40-F5-2
90 460 430 490 CXM-4-35-90-18-AC40-F5-3 CXM-4-35-90-18-AC40-F5-2
95 435 405 465 CXM-4-35-95-18-AC40-F5-3 CXM-4-35-95-18-AC40-F5-2
80 4000K 550 510 590 CXM-4-40-80-18-AC40-F5-3 CXM-4-40-80-18-AC40-F5-2
90 465 430 500 CXM-4-40-90-18-AC40-F5-3 CXM-4-40-90-18-AC40-F5-2
95 425 395 455 CXM-4-40-95-18-AC40-F5-3 CXM-4-40-95-18-AC40-F5-2
80 5000K 555 515 595 CXM-4-50-80-18-AC40-F5-3
90 470 435 505 CXM-4-50-90-18-AC40-F5-3
95 410 380 440 CXM-4-50-95-18-AC40-F5-3
80 5700K 550 510 590 CXM-4-57-80-18-AC40-F5-3
80 6500K 545 505 585 CXM-4-65-80-18-AC40-F5-3

 

Ordering Part Numbers -36 V

The following tables describe products with typical flux and minimum flux measured at 120 mA and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

Minimum-

CRI²

CCT Luminous Flux (Im)¹ Ordering Part Number
Typical Flux

(85°C)

Minimum

Flux (85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
90 2200K 375 350 400 CXM-4-22-90-36-AC40-F5-3 CXM-4-22-90-36-AC40-F5-2
90 2400K 390 365 415 CXM-4-24-90-36-AC40-F5-3 CXM-4-24-90-36-AC40-F5-2
80 2700K 505 470 540 CXM-4-27-80-36-AC40-F5-3 CXM-4-27-80-36-AC40-F5-2
90 415 385 445 CXM-4-27-90-36-AC40-F5-3 CXM-4-27-90-36-AC40-F5-2
95 390 365 415 CXM-4-27-95-36-AC40-F5-3 CXM-4-27-95-36-AC40-F5-2
80 3000K 520 485 555 CXM-4-30-80-36-AC40-F5-3 CXM-4-30-80-36-AC40-F5-2
90 440 410 470 CXM-4-30-90-36-AC40-F5-3 CXM-4-30-90-36-AC40-F5-2
95 405 375 435 CXM-4-30-95-36-AC40-F5-3 CXM-4-30-95-36-AC40-F5-2
80 3500K 540 500 580 CXM-4-35-80-36-AC40-F5-3 CXM-4-35-80-36-AC40-F5-2
90 460 430 490 CXM-4-35-90-36-AC40-F5-3 CXM-4-35-90-36-AC40-F5-2
95 435 405 465 CXM-4-35-95-36-AC40-F5-3 CXM-4-35-95-36-AC40-F5-2
80 4000K 550 510 590 CXM-4-40-80-36-AC40-F5-3 CXM-4-40-80-36-AC40-F5-2
90 465 430 500 CXM-4-40-90-36-AC40-F5-3 CXM-4-40-90-36-AC40-F5-2
95 425 395 455 CXM-4-40-95-36-AC40-F5-3 CXM-4-40-95-36-AC40-F5-2
80 5000K 555 515 595 CXM-4-50-80-36-AC40-F5-3
90 470 435 505 CXM-4-50-90-36-AC40-F5-3
95 410 380 440 CXM-4-50-95-36-AC40-F5-3
80 5700K 550 510 590 CXM-4-57-80-36-AC40-F5-3
80 6500K 545 505 585 CXM-4-65-80-36-AC40-F5-3

 

CCT, CRI and R9 Values

Correlated Color Temperatures XX Value CRI R91
2700K, 3000K, 3500K, 4000K, 5000K, 5700K, 6500K 80 >80 >0
2200K, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K, 6500K 90 >90 >50
2700K, 3000K 95 >95 >85
3500K, 4000K, 5000K >75

 

9 V

 

Parameter Symbol Value Unit
Forward Current Typical If typ 480 mA
Maximum If max 1600
Power Dissipation Typical Pd typ 4 W
Maximum Pd max 7.5
Operating Case Temperature Maximum Tc 120 °C
Junction Temperature Maximum T

j

140 °C

 

18 V

Parameter Symbol Value Unit
Forward Current Typical If typ 240 mA
Maximum If max 800
Power Dissipation Typical Pd typ 4 W
Maximum Pd max 7.5
Operating Case Temperature Maximum Tc 120 °C
Junction Temperature Maximum T

j

140 °C

 

36 V

Parameter Symbol Value Unit
Forward Current Typical If typ 120 mA
Maximum If max 400
Power Dissipation Typical Pd typ 4 W
Maximum Pd max 7.5
Operating Case Temperature Maximum Tc 120 °C
Junction Temperature Maximum T

j

140 °C

 

product-770-769