Pure White Targeted COB Arrays Below the Black Body Locus (BBBL)

Categories: ,

Description

Generation 4 Sensus™ LED Series

Features
• Matching the human perception of “Pure white” light
• Designed to provide the look and feel of ceramic metal halide lights
• Wide product range from 1,000lm to over 15,000lm
• 2700K, 3000K and 3500K, 80 and 90CRI standard
• Market specific 3200K, 95CRI Fashion Series
• Highly saturated color rendering version in 2700K, 3000K and 3500K
• 3 SDCM color binning standard, 2 SDCM binning available
• Excellent optical emission uniformitvy and color over angle consistency
• Exceptional long term color stability
• Superior thermal conductivity for uniform heat spreading
• Environmentally friendly: RoHS and REACH compliant
• UL recognized, file # E465703

Applications
• Spotlights/Track Lights
• Downlights
• Shop Lighting
• Hospitality Lighting
• Architectural and Specialty
• Street Lighting
• Parking Lot and Area Lighting
• Tunnel Lighting

 

CCT, CRI and R9 Values

Correlated Color Temperatures XX Value CRI *R9
2700K, 3000K 80 >80 >0
2700K, 3000K, 3100K, 3500K 90 >90 >50
3200K 95 >95 >85

 

Ordering Part Numbers – Sensus

The following tables describe products with typical flux and minimum flux measured attypcal current and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only.

Output Flux (lm) LES

Diamenter

(mm)

Typ .

Current

(mA)

Ordering Part Number
Typ. (85ºC) Min. (85ºC) Calculated

Typ. (25ºC)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
600 560 640 6.3 300 CXM-6-27-90-18-AC42-F5-3 CXM-6-27-90-18-AC42-F5-2
740 690 790 CXM-6-30-80-18-AC42-F5-3 CXM-6-30-80-18-AC42-F5-2
655 610 700 CXM-6-30-90-18-AC42-F5-3 CXM-6-30-90-18-AC42-F5-2
655 610 700 CXM-6-31-90-18-AC42-F5-3 CXM-6-31-90-18-AC42-F5-2
680 630 730 CXM-6-35-90-18-AC42-F5-3 CXM-6-35-90-18-AC42-F5-2
720 670 775 150 CXM-6-27-80-36-AC42-F5-3 CXM-6-27-80-36-AC42-F5-2
600 560 640 CXM-6-27-90-36-AC42-F5-3 CXM-6-27-90-36-AC42-F5-2
740 690 790 CXM-6-30-80-36-AC42-F5-3 CXM-6-30-80-36-AC42-F5-2
655 610 700 CXM-6-30-90-36-AC42-F5-3 CXM-6-30-90-36-AC42-F5-2
655 610 700 CXM-6-31-90-36-AC42-F5-3 CXM-6-31-90-36-AC42-F5-2
680 630 730 CXM-6-35-90-36-AC42-F5-3 CXM-6-35-90-36-AC42-F5-2
745 695 795 9.8 360 CIM-9-27-90-18-AC42-F5-3 CIM-9-27-90-18-AC42-F5-2
915 850 980 CIM-9-30-80-18-AC42-F5-3 CIM-9-30-80-18-AC42-F5-2
810 755 865 CIM-9-30-90-18-AC42-F5-3 CIM-9-30-90-18-AC42-F5-2
845 785 905 CIM-9-35-90-18-AC42-F5-3 CIM-9-35-90-18-AC42-F5-2
745 695 795 180 CIM-9-27-90-36-AC42-F5-3 CIM-9-27-90-36-AC42-F5-2
915 850 980 CIM-9-30-80-36-AC42-F5-3 CIM-9-30-80-36-AC42-F5-2
810 755 865 CIM-9-30-90-36-AC42-F5-3 CIM-9-30-90-36-AC42-F5-2
845 785 905 CIM-9-35-90-36-AC42-F5-3 CIM-9-35-90-36-AC42-F5-2
1,000 930 1,070 9.8 500 CLM-9-27-90-18-AC42-F5-3 CLM-9-27-90-18-AC42-F5-2
1,095 1,020 1,170 CLM-9-30-90-18-AC42-F5-3 CLM-9-30-90-18-AC42-F5-2
1,095 1,020 1,170 CLM-9-31-90-18-AC42-F5-3 CLM-9-31-90-18-AC42-F5-2
1,135 1,055 1,215 CLM-9-35-90-18-AC42-F5-3 CLM-9-35-90-18-AC42-F5-2
1,000 930 1,070 250 CLM-9-27-90-36-AC42-F5-3 CLM-9-27-90-36-AC42-F5-2
1,235 1,150 1,320 CLM-9-30-80-36-AC42-F5-3 CLM-9-30-80-36-AC42-F5-2
1,095 1,020 1,170 CLM-9-30-90-36-AC42-F5-3 CLM-9-30-90-36-AC42-F5-2
1,095 1,020 1,170 CLM-9-31-90-36-AC42-F5-3 CLM-9-31-90-36-AC42-F5-2
1,135 1,055 1,215 CLM-9-35-90-36-AC42-F5-3 CLM-9-35-90-36-AC42-F5-2

 

Ordering Part Numbers – Sensus

The following tables describe products with typical flux and minimum flux measured attypcal current and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only.

Output Flux (lm) LES

Diamenter

(mm)

Typ .

Current

(mA)

Ordering Part Number
Typ. (85ºC) Min. (85ºC) Calculated

Typ. (25ºC)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
1,000 930 1,070 9.8 250 CLM-9-27-90-36-AA42-F5-3 CLM-9-27-90-36-AA42-F5-2
1,235 1,150 1,320 CLM-9-30-80-36-AA42-F5-3 CLM-9-30-80-36-AA42-F5-2
1,095 1,020 1,170 CLM-9-30-90-36-AA42-F5-3 CLM-9-30-90-36-AA42-F5-2
1,135 1,055 1,215 CLM-9-35-90-36-AA42-F5-3 CLM-9-35-90-36-AA42-F5-2
1,110 1,035 1,190 CLM-9-40-90-36-AA42-F5-3 CLM-9-40-90-36-AA42-F5-2
1,415 1,315 1,515  

9.8

 

360

CXM-9-27-90-36-AA42-F5-3 CXM-9-27-90-36-AA42-F5-2
1,745 1,625 1,865 CXM-9-30-80-36-AA42-F5-3 CXM-9-30-80-36-AA42-F5-2
1,550 1,440 1,660 CXM-9-30-90-36-AA42-F5-3 CXM-9-30-90-36-AA42-F5-2
1,610 1,495 1,725 CXM-9-35-90-36-AA42-F5-3 CXM-9-35-90-36-AA42-F5-2
1,580 1,470 1,700 CXM-9-40-90-36-AA42-F5-3 CXM-9-40-90-36-AA42-F5-2
1,415 1,315 1,515 CXM-9-27-90-36-AC42-F5-3 CXM-9-27-90-36-AC42-F5-2
1,745 1,625 1,865 CXM-9-30-80-36-AC42-F5-3 CXM-9-30-80-36-AC42-F5-2
1,550 1,440 1,660 CXM-9-30-90-36-AC42-F5-3 CXM-9-30-90-36-AC42-F5-2
1,550 1,440 1,660 CXM-9-31-90-36-AC42-F5-3 CXM-9-31-90-36-AC42-F5-2
1,835 1,705 1,960 CXM-9-35-80-36-AC42-F5-3 CXM-9-35-80-36-AC42-F5-2
1,610 1,495 1,725 CXM-9-35-90-36-AC42-F5-3 CXM-9-35-90-36-AC42-F5-2
1,580 1,470 1,700 CXM-9-40-90-36-AC42-F5-3 CXM-9-40-90-36-AC42-F5-2
1,825 1,695 1,955 11.6 450 CXM-11-27-90-36-AA42-F5-3 CXM-11-27-90-36-AA42-F5-2
2,250 2,095 2,410 CXM-11-30-80-36-AA42-F5-3 CXM-11-30-80-36-AA42-F5-2
1,995 1,855 2,135 CXM-11-30-90-36-AA42-F5-3 CXM-11-30-90-36-AA42-F5-2
2,075 1,930 2,220 CXM-11-35-90-36-AA42-F5-3 CXM-11-35-90-36-AA42-F5-2
1,825 1,695 1,955 CXM-11-27-90-36-AC442-F5-3 CXM-11-27-90-36-AC442-F5-2
2,250 2,095 2,410 CXM-11-30-80-36-AC442-F5-3 CXM-11-30-80-36-AC442-F5-2
1,995 1,855 2,135 CXM-11-30-90-36-AC442-F5-3 CXM-11-30-90-36-AC442-F5-2
2,075 1,930 2,220 CXM-11-35-90-36-AC442-F5-3 CXM-11-35-90-36-AC442-F5-2

 

Ordering Part Numbers – Sensus

The following tables describe products with typical flux and minimum flux measured attypcal current and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only.

Output Flux (lm) LES

Diamenter

(mm)

Typ .

Current

(mA)

Ordering Part Number
Typ. (85ºC) Min. (85ºC) Calculated

Typ. (25ºC)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
1,870 1,740 2,000 14.5 450 CIM-14-27-90-36-AC42-F5-3 CIM-14-27-90-36-AC42-F5-2
2,305 2,145 2,465 CIM-14-30-80-36-AC42-F5-3 CIM-14-30-80-36-AC42-F5-2
2,045 1,900 2,190 CIM-14-30-90-36-AC42-F5-3 CIM-14-30-90-36-AC42-F5-2
2,125 1,975 2,275 CIM-14-35-90-36-AC42-F5-3 CIM-14-35-90-36-AC42-F5-2
2,075 1,930 2,220 14.5 500 CLM-14-27-90-36-AA42-F5-3 CLM-14-27-90-36-AA42-F5-2
2,560 2,380 2,740 CLM-14-30-80-36-AA42-F5-3 CLM-14-30-80-36-AA42-F5-2
2,270 2,110 2,430 CLM-14-30-90-36-AA42-F5-3 CLM-14-30-90-36-AA42-F5-2
2,360 2,195 2,525 CLM-14-35-90-36-AA42-F5-3 CLM-14-35-90-36-AA42-F5-2
2,310 2,150 2,470 CLM-14-40-90-36-AA42-F5-3 CLM-14-40-90-36-AA42-F5-2
2,075 1,930 2,220 CLM-14-27-90-36-AC42-F5-3 CLM-14-27-90-36-AC42-F5-2
2,560 2,380 2,740 CLM-14-30-80-36-AC42-F5-3 CLM-14-30-80-36-AC42-F5-2
2,270 2,110 2,430 CLM-14-30-90-36-AC42-F5-3 CLM-14-30-90-36-AC42-F5-2
2,270 2,110 2,430 CLM-14-31-90-36-AC42-F5-3 CLM-14-31-90-36-AC42-F5-2
2,360 2,195 2,525 CLM-14-35-90-36-AC42-F5-3 CLM-14-35-90-36-AC42-F5-2
2,990 2,780 3,200 14.5 720 CXM-14-27-90-36-AC42-F5-3 CXM-14-27-90-36-AC42-F5-2
3,685 3,425 3,945 CXM-14-30-80-36-AC42-F5-3 CXM-14-30-80-36-AC42-F5-2
3,265 3,035 3,495 CXM-14-30-90-36-AC42-F5-3 CXM-14-30-90-36-AC42-F5-2
3,265 3,035 3,495 CXM-14-31-90-36-AC42-F5-3 CXM-14-31-90-36-AC42-F5-2
3,164 2,940 3,387 CXM-14-32-95-36-AC42-F5-3 CXM-14-32-95-36-AC42-F5-2
3,395 3,155 3,635 CXM-14-35-90-36-AC42-F5-3 CXM-14-35-90-36-AC42-F5-2
2,990 2,780 3,200 CXM-14-27-90-36-AA42-F5-3 CXM-14-27-90-36-AA42-F5-2
3,685 3,425 3,945 CXM-14-30-80-36-AA42-F5-3 CXM-14-30-80-36-AA42-F5-2
3,265 3,035 3,495 CXM-14-30-90-36-AA42-F5-3 CXM-14-30-90-36-AA42-F5-2
3,395 3,155 3,635 CXM-14-35-90-36-AA42-F5-3 CXM-14-35-90-36-AA42-F5-2
3,595 3,345 3,845 14.5 900 CGM-14-27-90-36-AC42-F5-3 CGM-14-27-90-36-AC42-F5-2
4,435 4,125 4,745 CGM-14-30-80-36-AC42-F5-3 CGM-14-30-80-36-AC42-F5-2
3,930 3,655 4,205 CGM-14-30-90-36-AC42-F5-3 CGM-14-30-90-36-AC42-F5-2
4,085 3,800 4,370 CGM-14-35-90-36-AC42-F5-3 CGM-14-35-90-36-AC42-F5-2

 

Ordering Part Numbers – Sensus

The following tables describe products with typical flux and minimum flux measured attypcal current and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only.

Output Flux (lm) LES

Diamenter

(mm)

Typ .

Current

(mA)

Ordering Part Number
Typ. (85ºC) Min. (85ºC) Calculated

Typ. (25ºC)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
3,365 3,130 3,600 17.5 800 CXM-18-27-90-36-AA42-F5-3 CXM-18-27-90-36-AA42-F5-2
3,680 3,420 3,940 CXM-18-30-90-36-AA42-F5-3 CXM-18-30-90-36-AA42-F5-2
3,825 3,555 4,095 CXM-18-35-90-36-AA42-F5-3 CXM-18-35-90-36-AA42-F5-2
4,570 4,250 4,890 22.0 990 CIM-22-30-90-36-AC42-F5-3 CIM-22-30-90-36-AC42-F5-2
4,750 4,420 5,085 CIM-22-35-90-36-AC42-F5-3 CIM-22-35-90-36-AC42-F5-2
4,485 4,170 4,800 22.0 1050 CLM-22-27-90-36-AC42-F5-3 CLM-22-27-90-36-AC42-F5-2
4,905 4,560 5,250 CLM-22-30-90-36-AC42-F5-3 CLM-22-30-90-36-AC42-F5-2
4,905 4,560 5,250 CLM-22-31-90-36-AC42-F5-3 CLM-22-31-90-36-AC42-F5-2
4,750 4,418 5,083 CLM-22-32-95-36-AC42-F5-3 CLM-22-32-95-36-AC42-F5-2
5,095 4,740 5,450 CLM-22-35-90-36-AC42-F5-3 CLM-22-35-90-36-AC42-F5-2
7,225 6,720 7,730 22.0 1050 CXM-22-30-90-54-AC42-F5-3 CXM-22-30-90-54-AC42-F5-2
7,515 6,990 8,040 CXM-22-35-90-54-AC42-F5-3 CXM-22-35-90-54-AC42-F5-2
10,705 9,955 11,455 22.0 1600 CGM-22-30-90-54-AC42-F5-3 CGM-22-30-90-54-AC42-F5-2
11,130 10,350 11,910 CGM-22-35-90-54-AC42-F5-3 CGM-22-35-90-54-AC42-F5-2
16,190 15,055 17,325 32.8 2400 CXM-32-30-90-54-AC42-F5-3 CXM-32-30-90-54-AC42-F5-2
16,830 15,650 18,010 CXM-32-35-90-54-AC42-F5-3 CXM-32-35-90-54-AC42-F5-2

 

Ordering Part Numbers  Xtreme Sensus

The following tables describe products with typical flux and minimum flux measured attypcal current and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only.

Output Flux (lm) LES

Diamenter

(mm)

Typ .

Current

(mA)

Ordering Part Number
Typ. (85ºC) Min. (85ºC) Calculated

Typ. (25ºC)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
600 560 640 6.3 300 CXM-6-30-90-18-AC44-F5-3 CXM-6-30-90-18-AC44-F5-2
620 575 665 CXM-6-35-90-18-AC44-F5-3 CXM-6-35-90-18-AC44-F5-2
600 560 640 150 CXM-6-30-90-36-AC44-F5-3 CXM-6-30-90-36-AC44-F5-2
620 575 665 CXM-6-35-90-36-AC44-F5-3 CXM-6-35-90-36-AC44-F5-2
745 695 795 9.8 180 CIM-9-30-90-36-AC44-F5-3 CIM-9-30-90-36-AC44-F5-2
770 715 825 CIM-9-35-90-36-AC44-F5-3 CIM-9-35-90-36-AC44-F5-2
745 695 795 360 CIM-9-30-90-18-AC44-F5-3 CIM-9-30-90-18-AC44-F5-2
770 715 825 CIM-9-35-90-18-AC44-F5-3 CIM-9-35-90-18-AC44-F5-2
1,000 930 1,070 9.8 250 CLM-9-30-90-36-AC44-F5-3 CLM-9-30-90-36-AC44-F5-2
1,035 965 1,105 CLM-9-35-90-36-AC44-F5-3 CLM-9-35-90-36-AC44-F5-2
1,420 1,320 1,520 9.8 360 CXM-9-30-90-36-AA44-F5-3 CXM-9-30-90-36-AA44-F5-2
1,470 1,365 1,575 CXM-9-35-90-36-AA44-F5-3 CXM-9-35-90-36-AA44-F5-2
1,420 1,320 1,520 CXM-9-30-90-36-AC44-F5-3 CXM-9-30-90-36-AC44-F5-2
1,470 1,365 1,575 CXM-9-35-90-36-AC44-F5-3 CXM-9-35-90-36-AC44-F5-2
1,830 1,700 1,960 11.6 450 CXM-11-30-90-36-AA44-F5-3 CXM-11-30-90-36-AA44-F5-2
1,890 1,760 2,020 CXM-11-35-90-36-AA44-F5-3 CXM-11-35-90-36-AA44-F5-2
1,875 1,745 2,005 14.5 450 CIM-14-30-90-36-AC44-F5-3 CIM-14-30-90-36-AC44-F5-2
1,940 1,805 2,075 CIM-14-35-90-36-AC44-F5-3 CIM-14-35-90-36-AC44-F5-2
2,080 1,935 2,225 14.5 500 CLM-14-30-90-36-AC44-F5-3 CLM-14-30-90-36-AC44-F5-2
2,150 2,000 2,300 CLM-14-35-90-36-AC44-F5-3 CLM-14-35-90-36-AC44-F5-2
2,995 2,785 3,205 14.5 720 CXM-14-30-90-36-AC44-F5-3 CXM-14-30-90-36-AC44-F5-2
3,100 2,885 3,315 CXM-14-35-90-36-AC44-F5-3 CXM-14-35-90-36-AC44-F5-2
2,995 2,785 3,205 CXM-14-30-90-36-AA44-F5-3 CXM-14-30-90-36-AA44-F5-2
3,100 2,885 3,315 CXM-14-35-90-36-AA44-F5-3 CXM-14-35-90-36-AA44-F5-2
3,600 3,350 3,850 14.5 900 CGM-14-30-90-36-AC44-F5-3 CGM-14-30-90-36-AC44-F5-2
3,725 3,465 3,985 CGM-14-35-90-36-AC44-F5-3 CGM-14-35-90-36-AC44-F5-2

 

Ordering Part Numbers  Xtreme Sensus

The following tables describe products with typical flux and minimum flux measured attypcal current and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only.

Output Flux (lm) LES

Diamenter

(mm)

Typ .

Current

(mA)

Ordering Part Number
Typ. (85ºC) Min. (85ºC) Calculated

Typ. (25ºC)

3-step MacAdam Ellipse 2-step MacAdam Ellipse
3,375 3,140 3,610 17.5 800 CXM-18-30-90-36-AA44-F5-3 CXM-18-30-90-36-AA44-F5-2
3,490 3,245 3,735 CXM-18-35-90-36-AA44-F5-3 CXM-18-35-90-36-AA44-F5-2
4,190 3,895 4,485 22.0 990 CIM-22-30-90-36-AC44-F5-3 CIM-22-30-90-36-AC44-F5-2
4,330 4,025 4,635 CIM-22-35-90-36-AC44-F5-3 CIM-22-35-90-36-AC44-F5-2
4,495 4,180 4,810 22.0 1050 CLM-22-30-90-36-AC44-F5-3 CLM-22-30-90-36-AC44-F5-2
4,650 4,325 4,975 CLM-22-35-90-36-AC44-F5-3 CLM-22-35-90-36-AC44-F5-2
6,625 6,160 7,090 22.0 1050 CXM-22-30-90-54-AC44-F5-3 CXM-22-30-90-54-AC44-F5-2
6,850 6,370 7,330 CXM-22-35-90-54-AC44-F5-3 CXM-22-35-90-54-AC44-F5-2
9,815 9,130 10,500 22.0 1600 CGM-22-30-90-54-AC44-F5-3 CGM-22-30-90-54-AC44-F5-2
10,150 9,440 10,860 CGM-22-35-90-54-AC44-F5-3 CGM-22-35-90-54-AC44-F5-2
14,840 13,800 15,880 32.8 2400 CXM-32-30-90-54-AC44-F5-3 CXM-32-30-90-54-AC44-F5-2
15,350 14,275 16,425 CXM-32-35-90-54-AC44-F5-3 CXM-32-35-90-54-AC44-F5-2

 

CXM-6 Operating Characteristics1

Parameter – 36V Symbol Minimum Typical Maximum Unit
Forward Current2 If 150 450 mA
Forward Voltage3 Vf 31.0 33.6 37.0 V
Parameter – 18V Symbol Minimum Typical Maximum Unit
Forward Current2 If 300 900 mA
Forward Voltage3 Vf 15.5 16.8 18.5 V

 

Parameter Symbol Minimum Typical Maximum Unit
Power 5.0 17.1 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 6.3 mm
Thermal Resistance (junction-to-case) Θjc 1.0 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CIM-9 Operating Characteristics1

Parameter – 36V Symbol Minimum Typical Maximum Unit
Forward Current2 If 180 500 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Parameter – 18V Symbol Minimum Typical Maximum Unit
Forward Current2 If 360 1000 mA
Forward Voltage3 Vf 15.5 16.7 18.5 V
Parameter Symbol Minimum Typical Maximum Unit
Power 6.1 19.9 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 9.8 mm
Thermal Resistance (junction-to-case) Θjc 0.70 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CLM-9 Operating Characteristics1

Parameter -36V Symbol Minimum Typical Maximum Unit
Forward Current2 If 250 900 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Parameter -18V Symbol Minimum Typical Maximum Unit
Forward Current2 If 500 1800 mA
Forward Voltage3 Vf 15.5 16.7 18.5 V
Parameter Symbol Minimum Typical Maximum Unit
Power 8.3 34.4 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 9.8 mm

 

CXM-9 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 360 1,100 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Power 12.1 41.9 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 9.8 mm
Thermal Resistance (junction-to-case) Θjc 0.32 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CXM-11 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 450 1,300 mA
Forward Voltage3 Vf 31.0 33.7 37.0 V
Power 15.1 49.3 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 11.6 mm
Thermal Resistance (junction-to-case) Θjc 0.29 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CIM-14 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 450 1,300 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Power 15.1 49.3 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 14.5 mm
Thermal Resistance (junction-to-case) Θjc 0.28 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CLM-14 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 500 1,800 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Power 16.6 68.7 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 14.5 mm
Thermal Resistance (junction-to-case) Θjc 0.25 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CXM-14 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 720 2,000 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Power 24.1 75.6 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 14.5 mm
Thermal Resistance (junction-to-case) Θjc 0.23 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CGM-14 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 900 2,300 mA
Forward Voltage3 Vf 31.0 34.4 37.0 V
Power 30.4 86.3 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 14.5 mm
Thermal Resistance (junction-to-case) Θjc 0.22 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CXM-18 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 800 2,500 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Power 26.8 93.8 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 17.5 mm
Thermal Resistance (junction-to-case) Θjc 0.17 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CIM-22 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 990 3,000 mA
Forward Voltage3 Vf 31.0 33.3 37.0 V
Power 33.2 112.5 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 22.0 mm
Thermal Resistance (junction-to-case) Θjc 0.16 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CLM-22 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 1,050 3,500 mA
Forward Voltage3 Vf 31.0 33.5 37.0 V
Power 35.2 131.3 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 22.0 mm
Thermal Resistance (junction-to-case) Θjc 0.14 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CXM-22 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 1,050 3,500 mA
Forward Voltage3 Vf 48.0 50.0 55.0 V
Power 52.8 198.7 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 22.0 mm
Thermal Resistance (junction-to-case) Θjc 0.12 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CGM-22 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 1,600 4,000 mA
Forward Voltage3 Vf 48.0 50.8 55.0 V
Power 81.1 225.7 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 22.0 mm
Thermal Resistance (junction-to-case) Θjc 0.11 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree

 

CXM-32 Operating Characteristics1

Parameter Symbol Minimum Typical Maximum Unit
Forward Current2 If 2,400 5,000 mA
Forward Voltage3 Vf 48.0 50.8 55.0 V
Power 122.9 284.8 W
Operating Case Temperature T c 120 ºC
Light Emitting Surface Diameter LES 32.8 mm
Thermal Resistance (junction-to-case) Θjc 0.07 ºC/W
Junction Temperature Tj 140 ºC
Viewing Angle 120 Degree