Bridgelux® Vesta® SE Series Dim-To-Warm Gen1 18mm Integrated Array with S2 Holder

Description

Bridgelux® Vesta® SE Series Dim-To-Warm Gen1 18mm Integrated Array with S2 Holder

Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The arrays incorporate several features to simplify design integration and assembly.

 

product-852-521

Product Family Product Part Number Doc Number Gen LES Size (mm) CCT Range (K) CRI Typ. FLUX (lm) highest CCT Current (mA) Voltage (V) Power (W) Efficacy (lm/W) Substrate Size (mm)
BXRV Vesta DW Vesta SE Dim to Warm 18mm BXRV-DR-1827G-4000-A13-S2 DS374 1 ⌀18.3 1800-2700 90 4675 1290 33.8 43.6 107 ⌀45
BXRV Vesta DW Vesta SE Dim to Warm 18mm BXRV-DR-1827H-4000-A13-S2 DS374 1 ⌀18.3 1800-2700 95 4133 1290 33.8 43.6 95 ⌀45
BXRV Vesta DW Vesta SE Dim to Warm 18mm BXRV-DR-1830G-4000-A13-S2 DS374 1 ⌀18.3 1800-3000 90 4887 1290 33.8 43.6 112 ⌀45
BXRV Vesta DW Vesta SE Dim to Warm 18mm BXRV-DR-1830H-4000-A13-S2 DS374 1 ⌀18.3 1800-3000 95 4386 1290 33.8 43.6 101 ⌀45

 

Table 1: Selection Guide, Measurement Data

Part Number Nominal

CCT1

Tc=25°C

(K)

Minimum

CRI 2

Nominal

Drive

Current

(mA)

Typical Vf

Tc=25°C

(V)

Typical

Power

Tc=25°C

(W)

Typical

Pulsed

Flux 3, 4, 5

Tc=25°C

(lm)

Typical

Efficacy

Tc=25°C

(lm/W)

Minimum

Pulsed

Flux 6

Tc=25°C

(lm)

Typical

DC Flux 7, 8

Tc=85°C

(lm)

BXRV-DR-1827G-4000-A-

13-S2

2700 90 1290 33.8 43.6 4675 107 4207 4207
1800 90 20 26.4 0.5 55 104 50 50
BXRV-DR-1827H-4000-A-

13-S2

2700 95 1290 33.8 43.6 4133 95 3719 3719
1800 93 20 26.4 0.5 37 70 33 33
BXRV-DR-1830G-4000-A-

13-S2

3000 90 1290 33.8 43.6 4887 112 4398 4398
1800 90 20 26.4 0.5 56 106 50 50
BXRV-DR-1830H-4000-A-

13-S2

3000 95 1290 33.8 43.6 4386 101 3948 3948
1800 93 20 26.4 0.5 48 90 43 43

 

Table 2: Table of products registered in the European Product Registry for Energy Labeling (EPREL)

product-2-3Part Number

 

CCT

(K)

CRI Cur

rent 3

(mA)

Volt

age 3

(V)

Useful

Flux 2

useful

Tc=85C

(lm)

Power

(W)

Efficacy

(lm/W)

Energy

Efficiency

Class 4

Regis

tration

No

 
BXRV-DR-1827G-4000-A-

13-S2

2700 90 1400 34.1 4191 47.8 87 G 876474
BXRV-DR-1827H-4000-A-

13-S2

2700 95 470 30.6 1386 14.4 96 F 876488
BXRV-DR-1830G-4000-A-

13-S2

3000 90 1400 34.1 4381 47.8 91 G 876505
BXRV-DR-1830H-4000-A-

13-S2

3000 95 960 32.5 2852 31.2 91 G 876519

 

Table 3: Electrical Characteristics

Part Number Drive

Current

(mA)

Forward Voltage

Pulsed, T= 25.C 1, 2, 3, 7

Typical

Coefficient

of Forward

Voltage

∆Vf/∆Tc

(mV/ºC)

Typical

Thermal

Resistance

Junction to

Case4, 5

(ºC/W)

Driver Selection

Voltages 6

Minimum

(V)

Typical

(V)

Maximum

(V)

Vf Min. Hot

Tc = 105ºC

(V)

Vf Max. Cold

Tc = -40ºC

(V)

BXRV-DR-18xxx-4000-A-

13-S2

1290 32.1 33.8 35.5 -12.8 0.14 31.2 36.5
1400 32.4 34.1 35.8 -12.8 0.15 31.5 36.8

 

Table 4: Maximum Ratings

Parameter Maximum Rating
LED Junction Temperature (Tj) 125°C
Storage Temperature -40.C to +105.C
Operating Case Temperature1 (Tc) 105°C
Maximum Drive Current3 1400mA
Maximum Peak Pulsed Drive Current4 1950mA
Maximum Reverse Voltage5 -60V

 